Certifications and approvals - Underwriters Lab, Canadian Standards Association, Restriction of Hazardous Substances, and Mil Spec approvals

Military Grade / MIL-SPEC Chlorinated Polyolefin Neoprene Shrink Tube M23053/1-103-0

NEOPRENE MILSPEC HEAT SHRINK TUBE

  • FLAME RETARDANT
  • RoHS COMPLIANT


Size
-
1/2 in.
Spool Size
-
100 ft.
Color
-
Black

Availability: Verify Availability Before Ordering

Description

Details

Gamma’s Neoprene (NP) series is a Crosslinked Chlorinated Polyolefin Flexible Heat Shrink tubing, which is used for insulation, strain relief, and abrasion protection on cable harnesses and wire bundles in military and aerospace industries. NP Neoprene provides fluid and solvent resistance, including lubricating oil, aviation and ground-vehicle fuels and hydraulic fluids. Neoprene remains flexible at low temperatures.

  • The heat shrinkable tube M23053/1-103-0 supplied Inside Diameter is 0.500 inch (12.7 mm). After Unrestricted shrinkage, the Inside Diameter is maximum of 0.286 inch (7.3 mm).
  • After heating, the Wall Thickness for this heat shrinking tube will be 0.048 ± 0.015 inch (1.21 ± 0.38 mm).
  • Continuous operating temperature range of -55°C (-67°F) to +90°C (+194°F)
  • After Unrestricted Shrinkage, minimum Ultimate elongation is 225 percent
  • Longitudinal change + 1 percent
  • Heat Shrink Tubing is available in Black Color.

Key Features

Key Features

Crosslinked Chlorinated Polyolefin Heat Shrink Tube M23053/1-103-0 Features

  • SHRINK RATIO 2:1
  • 23053/1 CLASS 1
  • RoHS UL CERTIFIED
  • cUL CERTIFIED
  • Excellent general purpose, highly flexible insulation tube
  • Environmentally Friendly
  • Flame Retardant

M23053/1-103-0 Heat shrinkable flexible insulation sleeving is intended for use on cables or harness systems in equipment that is subject to high levels of physical abuse.

Specification

Specification

Military Grade / MIL-SPEC Polyolefin 2:1 Heat Shrink Tube M23053/1-103-0 Specification

Part No Minimum Inside Diameter as Supplied Maximum Inside Diameter After Shrinkage Wall Thickness After Shrinkage
  Mm Inch Mm Inch Mm Inch
M23053/1-101-0 6.4 0.250 3.6 0.143 0.89 ± 0.25 0.035 ± 0.010
M23053/1-102-0 9.5 0.375 5.4 0.211 1.01 ± 0.25 0.040 ± 0.010
M23053/1-103-0 12.7 0.500 7.3 0.286 1.21 ± 0.38 0.048 ± 0.015
M23053/1-104-0 15.9 0.625 9.1 0.357 1.32 ± 0.38 0.052 ± 0.015
M23053/1-105-0 19.1 0.750 10.9 0.428 1.44 ± 0.38 0.057 ± 0.015
M23053/1-106-0 22.2 0.875 12.7 0.500 1.65 ± 0.51 0.065 ± 0.020
M23053/1-107-0 25.4 1.000 14.5 0.570 1.77 ± 0.51 0.070 ± 0.020
M23053/1-108-0 31.8 1.250 18.1 0.714 2.20 ± 0.51 0.087 ± 0.020
M23053/1-109-0 38.1 1.500 21.8 0.857 2.41 ± 0.51 0.095 ± 0.020
M23053/1-110-0 44.5 1.750 25.4 1.000 2.71 ± 0.51 0.107 ± 0.020
M23053/1-111-0 50.8 2.000 29.0 1.140 2.79 ± 0.51 0.110 ± 0.020
M23053/1-112-0 76.2 3.000 43.4 1.710 3.17 ± 0.51 0.125 ± 0.020
M23053/1-113-0 101.6 4.000 57.9 2.280 3.55 ± 0.51 0.140 ± 0.020

Properties

Properties

Characteristic Requirement Test procedure and condition
As supplied:    

Low temperature flexibility

No cracks

-55° ± 2°C (-67° ± 4°F)

Heat shock No cracks, flowing or dripping

150° ± 2°C (302° ± 4°F)

Restricted shrinkage No cracks

135° ± 2°C (275° ± 4°F)

Voltage withstand Pass  
After unrestricted shrinkage:    
Tensile strength, psi (MPa), minimum 1,500 (10.3) ASTM D412
Ultimate elongation, percent, minimum 225 ASTM D412

Tensile stress, at 200 percent elongation
psi (MPa), maximum

1,500 (10.3) ASTM D412
Dielectric strength, Volts/roil (Kv/mm),
minimum

300 (11.8) - Up to 0.070 wall thickness
200 (7.8) - 0.070 and above

ASTM D2671
Volume resistivity, Ohm-cm, minimum

1 x 10^11

ASTM D876
Water absorption, percent, maximum 1.0

ASTM D570, 24 hrs at 23°C

Corrosion

No pitting or corrosion

150° ± 2°C (302° ± 4°F) for 16 hours.

Flammability No growth  
Heat resistance, property after:  

100° ± 2°C (212° ± 4°F), 96 hours

Tensile strength, psi (MPa), minimum 1,200  
Ultimate elongation, percent, minimum 150  
Dielectric strength volt/roil (Kv/mm),
minimum
300 (11.8)  
Fluid resistance, property after:    
Tensile strength, psi (MPa), minimum 900 (6.2)  
Ultimate elongation, percent, minimum 150  
Dielectric strength volt/roil (Kv/mm),
minimum
200 (7.9)  
Flammability

Self extinguishing 15 seconds; 3 inches

 
Fungus resistance 2 No growth ASTM G21